control and at the appliance openings. The recommended spa operating
environment is -5°C to +45°C, at 20-80 percent of relative humidity. Fuses are
covered to be free of defect at time of installation only.
Electrical Supply:
Insert the incoming electrical service line through
one of the access holes on either side of the spa
base (remove plastic plug). Then insert the service
through the electrical access hole of the control
box (see diagrams).
A pressure wire connector is located on the exterior of the control box. If the
installation includes a common bonding grid (reinforced concrete slab,
ground/earth plate beneath the spa, or any metal water pipe connection), this
pressure wire connector should be bonded to any metal ladder, water pipe, or
other metal, within 1.5 m of the spa and in accordance with pertinent electrical
codes.
220-240V AC, 50 Hz:
Connections shall be made in accordance with the wiring diagram found on the
inside of the control box cover. Connections should be made with copper
conductors only aluminum wiring should not be used with this system. All
conductors, circuit breakers, and/or fuses must be sized in accordance to the
input ratings shown below:
220-240 V AC, 50 Hz:
• Permanently connected
• Rated 220-240V AC 50 Hz
• One and two pump spas are rated 16A for low amp setting (heater off
during high-speed) and 32A for high amp setting (heater on during high-
speed).
Improperly wired spas can cause irreversible damage resulting in blown fuse
and melted terminal block, and to other electrical components. Also, damage
caused to components or equipment caused by high or low voltage, brown outs
or electric surges is not covered under warranty.
Electrical Service Connections at Terminal Block, Inside Spa Controller:
The spa must be supplied through a single MCB with a certified residual current
device (RCD) with a rated current trip not exceeding 30 mA. Means for spa
disconnection from supply must be incorporated in the fixed wiring.
Recommended supply conductor nominal cross sectional area is 4mm2 for 16A
rating, 6 mm2 for 32A rating.
NOTE: If the power cord on any piece of electrical equipment, such as a jet
pump or ozone generator, becomes damaged, do not use the spa until the cord
has been repaired. Consult your authorized Marquis Spas® dealer for
assistance on such repair.
Electrical Diagram: 322, 435, 545, 660
Improperly wired spas are beyond Marquis Corp. control and are not covered
under the warranty. Other items beyond Marquis Corp. control include, but are
not limited to, damage resulting from: improper connections; accidents; failure to
follow procedures and instructions defined in the Marquis Spas® printed
instructions; cleaning agents; and natural occurrences including but not limited
to rodent or insect infestation, mold, lightning and other acts of nature.