Marquis MQRB6961LPE Operations Instructions

Browse online or download Operations Instructions for Fireplaces Marquis MQRB6961LPE. Marquis MQRB6961LPE Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 122
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Infinite Series
Model Numbers:
MQRB4436N, MQRB4436NE, MQRB4436LP, MQRB4436LPE
MQRB5143N, MQRB5143NE, MQRB5143LP, MQRB5143LPE
MQRB6961N, MQRB6961NE, MQRB6961LP, MQRB6961LPE
Certified to:
ANSI Z21.50-2014 • CSA 2.22-2014
ZERO CLEARANCE VENTED GAS FIREPLACE
ZERO CLEARANCE VENTED GAS FIREPLACE
Installation Instructions
WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or maintenance can cause
property damage, personal injury or loss of life. Refer to this manual. Installation and service
must be performed by a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone.
If you cannot reach your gas supplier, call the fire department.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Page view 0
1 2 3 4 5 6 ... 121 122

Summary of Contents

Page 1 - Infinite Series

Infinite Series Model Numbers: MQRB4436N, MQRB4436NE, MQRB4436LP, MQRB4436LPE MQRB5143N, MQRB5143NE, MQRB5143LP, MQRB5143LPE MQRB6961N, MQRB6961

Page 2 - Table of Contents

MQRB4436 / MQRB5143 / MQRB6961 Nailing Tab Guide The Nailing Tabs on the MQRB4436, MQRB5143 or MQRB6961 can be used in two ways: 1/2” Drywall

Page 3

PVH58 Wiring Harness Connections WARNING WARNING WARNING A qualified electrician must connect electrical wiring to junction outle

Page 4 - ⚠ WARNING:

PVH58 Millivolt System Connections WHITEBLACK GREEN/GRND BROWNRED 10ft Double Pole Switch Wiring Harness for Millivolt Systems. Connects t

Page 5

MILLIVOLT POWER VENT CONTROL MODULE Connect to Power Vent CableConnect to Double Pole Switch CablePlug into120v AC OutletConnect to TH and TH / T

Page 6

PVCM Schematic - Millivolt 103

Page 7 - Operating Instructions

PVH58 IPI SYSTEM CONNECTIONS Mount Power Vent Control Module In Fireplace. Lamp Transformer housing may need to be moved toward va

Page 8

PVH58 Basic IPI System Connections RECOMMENDED METHOD OF CONNECTION: First ensure the entire IPI system is working properly without connecting a

Page 9 - Massachusetts

PVH58 All IPI System Connections RECOMMENDED METHOD OF CONNECTION: First ensure the entire IPI system is working properly without connecting any

Page 10 - -Fireplace to be covered

PVCM Schematic - IPI 107

Page 12

PVH58 Air Intake Adjustment The PVH58 is shipped with the air intake adjustment fully closed. This will produce maximum draw at the fireplace. L

Page 13 - Air Space

MQRB4436: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electric

Page 14 - [Steel Stud Framing Shown]

PVH58 Troubleshooting NOTE: Before connecting Power Vent Control Module, ensure that all other systems and accessories (Remote Control, Fan, Light

Page 15 - Steel Framing Studs

PVH58 Parts List PVH58 HORIZONTAL POWER VENT TERMINATION: Listed for Canada and USA NUMBER DESCRIPTION MQRB4436 AND MQRB5143 VENTING AND VENTING AD

Page 16

58PVH-P3211 3/4” K.O. Bushing 58PVH-WTA Wall Thimble Assembly PVH20H Main Wiring Harness Assembly – Extension Harness (20ft) PVC58MV Power Vent Con

Page 17

MQRB4436 Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -44” Wide Listed for USA/Canada as a Decorative Appliance: Lin

Page 18

ZDVSSLR Siding Shield - Large Return - for FDVHSQ or FDVHT ZDV48GP Galvanized Pipe 7" Dia. x 48" (Vertical Installations) ZDVAAF Flashing 7

Page 19 - Surround Clearances MQRB4436

MQRB5143 Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -51” Wide Listed for USA/Canada as a Decorative Appliance: Linear

Page 20

ZDVSS Siding Shield - Heat Deflector for FDVHT Round Termination ZDVSSLR Siding Shield - Large Return - for FDVHSQ or FDVHT ZDV48GP Galvanized Pipe 7&

Page 21 - MQRB4436 Mantel Clearances

MQRB6961 Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -69” Wide Listed for USA/Canada as a Decorative Appliance: Linear

Page 22

Z710GP48 Galvanized Pipe 10” Dia. X 4ft (Vertical Installation) Z710FS Firestop Spacer for 10” Pipe Z710RS Roof Support for 10” Pipe Z710FK5 Flex Kit

Page 23

Common Parts for MQRB4436, MQRB5143 and MQRB6961 Accessories Z1MT Thermostat (Not permitted for vented gas fireplaces installed in the U.S.A.) Milli

Page 24

MQRB4436 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to

Page 25

1002-P013si Stepper Motor (NG) 1002-P012si Stepper Motor (LP) 1002-P016si Hi/Lo Regulator (NG) 1002-P014si Hi/Lo Regulator (LP) Miscellaneous Part

Page 26

-Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. If the barrier becomes damaged

Page 27

This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation and only if the unit is installed insi

Page 28

MQRB4436 - Pre-existing Enclosures vs Framing Enclosure Around Fireplace Inserting Unit Into Pre-existing Enclosure: Enclosure must be 53-1/2” inside

Page 29 - 24” Min for Propane

MQRB4436 -See Through Framing An MQRB4436SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether th

Page 30 - Surround Clearances MQRB5143

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for

Page 31

MQRB4436 Single Sided Framing An MQRB4436BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surf

Page 32 - MQRB5143 Mantel Clearances

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non-C

Page 33

MQRB4436 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended

Page 34

Surround Dimensions MQRB4436 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness fo

Page 35

Table of Contents Table of Contents...

Page 36 - MQRB6961 See Thru Framing

MQRB4436 Facing Material Requirements These specifications are the same for all Models (4436N, 4436NE, 4436LP, 4436LPE). Note: If using Optional Surro

Page 37

MQRB4436 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of m

Page 38

MQRB5143: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electric

Page 39

MQRB5143 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to r

Page 40

MQRB5143 - Pre-existing Enclosures vs Framing Enclosure Around Fireplace Inserting Unit Into Pre-existing Enclosure: Enclosure must be 60-1/2” inside

Page 41 - Surround Clearances MQRB6961

MQRB5143 -See Through Framing An MQRB5143SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether th

Page 42

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for

Page 43 - MQRB6961 Mantel Clearances

MQRB5143 Single Sided Framing An MQRB5143BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surf

Page 44 - (Continued…)

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non-C

Page 45 - Panel Installation:

MQRB5143 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended

Page 46

MQRB5143 Burner Section: Gas Conversion...

Page 47

Surround Dimensions MQRB5143 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness

Page 48

MQRB5143 Facing Material Requirements These specifications are the same for all Models (5143N, 5143NE, 5143LP, 5143LPE). Note: If using Optional Surr

Page 49 - Using the Optional Surrounds

MQRB5143 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of ma

Page 50 - Surround Installation:

MQRB6961: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electric

Page 51

MQRB6961 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to

Page 52

MQRB6961 - Pre-existing Enclosures vs Framing Enclosure Around Fireplace Inserting Unit Into Pre-existing Enclosure: Enclosure must be 78-1/2” inside

Page 53 - ⚠ WARNING

MQRB6961 See Thru Framing MQRB6961SK Kit is required for a See Thru Installation. Before you begin Framing- Determine whether the Wall Surface will b

Page 54

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non-

Page 55

MQRB6961 Single Sided Framing An MQRB6961BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surf

Page 56 - Door and Glass Information

Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for Non

Page 57

Infinite Series CSS Child Safety Screen ⚠ WARNING: Wait until unit is COMPLETELY cool before touching glass or attempting to install or

Page 58 - Valve Access Cover Removal

MQRB6961 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended

Page 59 - Gas Line Installation

Surround Dimensions MQRB6961 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickness f

Page 60

MQRB6961 Facing Material Requirements These specifications are the same for all Models (6961N, 6961NE, 6961LP, 6961LPE). Note: If using Optional Surr

Page 61 - WARNING

MQRB6961 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of ma

Page 62 - -CAUTION

MQRB44BK / MQRB51BK / MQRB69BK Back Shield Kit –Single View *This Kit must be opened before unit is installed into Framing (See “Single Sided Framing”

Page 63

Back Liner, False Bottom, and End Panel Installation: 1. Remove Liner Clips from the inside of the Firebox (Fig.1). 2. Place the Back Liner onto th

Page 64

MQRB44SK / MQRB51SK / MQRB69SK (See Thru Kit) Installation This basic Kit is required for See Thru installations. Note: To cover the Side Fillers wit

Page 65 - -Warning

MQRB4436 / MQRB5143 / MQRB6961 Liner & False Bottom Installation Single Sided: Back Liner, End Panel, and False Bottom Installation: 1. R

Page 66

MQRB4436 / MQRB5143 / MQRB6961 Liner & False Bottom Installation See Thru: False Bottom & End Panel Installation: 1. False Bottom Insert

Page 67 - Warning

MQRB4436, MQRB5143 & MQRB6961 Finishing Options Using Side Fillers The Side Fillers are located at each side of the door. They are provided to

Page 68

MQRB69CSS Child Safety Screen ⚠ WARNING: Wait until unit is COMPLETELY cool before touching glass or attempting to install or remove Chi

Page 69

MQRB4436 / MQRB5143 / MQRB6961 Surround Installation Surround Kits are available in 3 different finishes: MQRB4436 MQRB5143 MQRB6961 Small [1-1/2”]

Page 70

Fan Installation MQRB4436 / MQRB5143 / MQRB6961 FAN KIT IS FOR USE IN BK (SINGLE SIDED) INSTALLATIONS ONLY Fan Kit should be installed before the fire

Page 71 - Remote Receiver Location

Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a

Page 72

MQRB4436 / MQRB5143 / MQRB6961 -Glass Ember Installation For best flame pattern it is essential to spread Crushed Glass or MQEMBER directl

Page 73

Optional Driftwood & Rock Installation NOTE: Only Crushed Glass or MQ Embers can be placed directly on Burner Tube. Model Part Number Description

Page 74 - -Remote Control Operation

 MQ46D Driftwood Log Set- 3pcs. (Single Sided Units Only)  Place Log 1 on left side of fireplace against the back wall of the firebox.  Place Log

Page 75

Door and Glass Information Glass Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms o

Page 76

Infinite Series Door Latch Tool MQRB4436 / MQRB5143 / MQRB6961 A Door Latch Tool is provided to assist with removing and installing the glass

Page 77

Valve Access Cover Removal Remove Valve Access Cover in order to access igniter and valve controls. To remove Valve Access Cover, simply insert finge

Page 78

Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CSA

Page 79

Recommendations for Finishing of Clean View Linear Products When finishing the wall around the fireplace, it is critical that the wall covering

Page 80 - TO TURN OFF GAS

Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING BEFORE LIGHTING A This appliance has a pilot which must be ligh

Page 81

Troubleshooting the Gas Control System Problem Possible Causes Corrective Action Defective or misaligned electrode at pilot. Check for spark at

Page 82

Burner System Maintenance- MQRB4436 / MQRB5143 / MQRB6961 It is recommended to annually inspect and clean the Burner System to prevent malfunction and

Page 83 - Venting

Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG

Page 84

Gas Conversion for Modulator – PART C -WARNING!- -WARNING!- 64

Page 85

MQRB4436 Burner Section: Gas Conversion Models: MQRB4436N, MQRB4436LP, MQRB4436NE, MQRB4436LPE. Kit Number Description Pilot Orifice Burner Orifice

Page 86 - Horizontal Vent Table

MQRB5143 Burner Section: Gas Conversion Models: MQRB5143N, MQRB5143LP, MQRB5143NE, MQRB5143LPE. Kit Number Description Pilot Orifice Burner Orifice

Page 87 - MQRB5143 Venting Examples

MQRB4436 / MQRB5143 Burner Tube Removal 1. Remove the six [6] DT screws from the lower portion of the Burner Tube Mount Brackets. 2. Slide the Bur

Page 88 - 52-1/4”Min

MQRB4436 / 5143 / 6961 Moving Valve to Other Side of Fireplace Warning: Failure to position the parts in accordance with these diagrams or failur

Page 89

MQRB6961 Burner Section: Gas Conversion Models: MQRB6961N, MQRB6961LP, MQRB6961NE, MQRB6961LPE. Kit Number Description Pilot Orifice Burner Orifice B

Page 90 - Roof Flashing

Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove pa

Page 91 - Z710VT for MQRB6961

MQRB6961 Burner Tube Removal 1. Remove the six [8] DT screws from the lower portion of the Burner Tube Mount Brackets. 2. Slide the Burner Tube awa

Page 92 - Flue Restrictor Adjustment

Remote Receiver Location For GT Series Remotes Only The Remote Receiver may be located inside of the unit- several inches to the left of the valve an

Page 93 - 58PVH-Dimensions

51-UHS For Infinite Series MQRB4436, MQRB5143, MQRB6961 The 51-UHS is designed for millivolt and IPI Infinite units for in-unit installation of the R

Page 94

IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standin

Page 95

-Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart

Page 96

IPI Electronic Ignition Parts List – Standard System ITEM NO. PART NO. DESCRIPTION 1 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/L

Page 97

Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities. 76

Page 98

Receiver Module .584.523/521/221 1001-P221SI Receiver Module.584.523/521/2211001-P221SI 77

Page 99 - PVH58 POWER VENT MOUNTING

Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivo

Page 100 - THE INSTALLATION

Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan inst

Page 101

Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local

Page 102

Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, p

Page 103 - PVCM Schematic - Millivolt

LK2 Halogen Lamp Kit MQRB4436 / MQRB5143 Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian Nation

Page 104 -

LK3 Halogen Lamp Kit (MQRB6961) Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Elect

Page 105

Venting WARNING: WHEN THE HORIZONTAL VENT TERMINATION IS ACCESSIBLE A CERTIFIED GUARD (SAFETY CAGE) SHALL BE INSTALLED. Notes: 1) Clearances are to t

Page 106

General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Ki

Page 107 - PVCM Schematic - IPI

Figure 1 - Flex pipe spring spacing guide. Horizontal runs require support metal straps every 2ft. In an offset installation support straps sh

Page 108

Minimum clearance to combustibles on venting is 1” with the following exceptions: MQRB4436 MQRB5143 MQRB6961 Top of horizontal 2” 2” 2” Top of 9

Page 109

MQRB5143 Venting Examples All horizontal runs have a minimum ¼” rise per foot. 52-1/4"Wall Thimble and Roof Support The Wall Thimble is used in

Page 110 - !WARNING

Installation of Side Wall Venting Vertical rise over 3ft horizontal run (MQRB5143 shown). Note that the minimum height from the bottom of fireplac

Page 111 - PVH58 Parts List

Z57ST24 / Z57ST36 Horizontal Snorkel Terminations MQRB4436 / MQRB5143 -FOR INFINITE SERIES II MODELS ONLY- Two snorkel terminations are avail

Page 112

 Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat

Page 113 - MQRB4436 Parts List

Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space wher

Page 114

Clearances in horizontal venting. Straight-through roof support configuration; b) Flex bend configuration; c) Termination mounting 2” Top of

Page 115 - MQRB5143 Parts List

Flue Restrictor Adjustment MQRB4436 / MQRB5143 Only –All Models The Flue Restrictor is located in the top of the Firebox in front of the Flue Opening

Page 116

5"1-1/2"1/2"10-5/8"1-1/4"8-1/8"12-1/2"16"58PVH-Dimensions13"13"10-5/8"11"13"11"1

Page 117 - MQRB6961 Parts List

PVH58 INSTALLATION OVERVIEW The PVH58 Horizontal Power Vent is approved for the following models only: MQRB4436, MQRB5143, MQRB6961 Either Hard Pi

Page 118 - ZDV710HSK5

PVH58 VENTING CLEARANCES A. Clearance above a veranda, porch, deck, or balcony or other combustible surface is 27”. Clearance above grade i

Page 119

PVH58 VENTING HARD PIPE OR FLEX Approved For 4/6-5/8”, 5/8” Hard Pipe The PVH-58 Power Vent is approved for use with DuraVent-DirectVent Pro Direc

Page 120 - Miscellaneous Parts

Approved For 4/7”, 5/7” And 7/10” Kingsman Flex (Z-Flex) Pipe Flex Pipe Venting Kingsman Flex pipe is shipped in unexpanded length. When installing pi

Page 121 - WARNING:

PVH58 VENTING CONFIGURATIONS Refer to Air Intake Adjustment section of this manual to adjust Air Intake Shutter. PVH-58 Maximum / Minimu

Page 122

PVH58 WALL THIMBLE INSTALLATION An 11 inch square opening is required. Center Wall Thimble over the 11 inch square opening and secure both pieces on e

Comments to this Manuals

No comments