\Çy|Ç|àx fxÜ|xá Model Number: MQRB5143 Stock Numbers: MQRB5143N, MQRB5143NE, MQRB5143LP, MQRB5143LPE Certified to: ANSI Z2
10 Surround Dimensions MQRB5143 • The Surround Frames are 1” thick, with a 3/4” space behind the frame. • When using Surrounds, Maximum Thickn
11MQRB5143 Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electr
12MQRB5143 Nailing Tab Guide The Nailing Tabs on the MQRB5143 can be used in two ways: 1/2” Drywall Flush with Face of Fireplace –Fireplace and
13 MQRB5143 -See Thru Framing An MQRB5143SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether t
14 Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness fo
15MQRB5143 Single Sided Framing An MQRB5143BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall S
16 Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace Note: If using Optional Surround, Maximum Thickness for No
17 MQRB5143 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recomme
18 MQRB5143 Facing Material Requirements These specifications are the same for all Models (5143N, 5143NE, 5143LP, 5143LPE). Note: If using Optional S
19 MQRB5143 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types o
2 Table of Contents Table of Contents ...
20MQRB5143 Finishing Options Using Side Fillers The Side Fillers are located at each side of the door. They are provided to give a continuous su
21 MQRB5143BK Back Shield Kit –Single View *This Kit must be opened before unit is installed into Framing (See “Single Sided Framing” page of this
22Back Liner, False Bottom, and End Panel Installation: 1. Remove Liner Clips from the inside of the Firebox. 2. Place the Back Liner into the Fir
23 MQRB5143SK (See Thru Kit) Installation This basic Kit is required for See Thru installations. Note: If you wish to cover the Side Fillers with no
24MQRB5143 Surround Installation The Surround Kits for the MQRB5143 are available in 3 different finishes: Small [1-1/2”] Large [4”] Surround Ki
25Optional Additional Screws: Stainless Steel Surrounds Two additional screws may be added to MQRB5019SS and MQRB5624SS to counteract heat distorti
26Optional Glass Ember Installation If you wish to use this media evenly spread the glass embers onto the false bottom and burner. Ensure the glass
27Door and Glass Information Glass Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, form
28Valve Access Cover Removal Remove Valve Access Cover in order to access igniter and valve controls. To remove Valve Access Cover, simply insert fi
29Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/
3Installers Note: ...
30Millivolt System, Lighting, and Burner Control
31Troubleshooting the Millivolt Gas Control System Problem Possible Causes Corrective Action Defective or misaligned electrode at pilot. Check for
32MQRB5143 Gas Conversion or Models: MQRB5143N, MQRB5143LP, MQRB5143NE, MQRB5143LPE. Kit Number Description Pilot Orifice Burner Orifice Nipple Ai
33 Gas Conversion for Top Convertible Pilot (Series 019065X) 1. Shut off the gas supply to the appliance. 2. Allow the pilot burner to cool to
34MQRB5143 Burner Tube Removal 1. Remove the six [6] DT screws from the lower portion of the Burner Tube Mount Brackets. 2. Slide the Burner Tube
35 Moving Valve to Other Side of Fireplace The Valve Assembly may be changed to the other side of the fireplace. This must be done Before the unit i
36IPI Electronic Ignition System SYSTEM NOTE In the event of an operational lockup the IPI system must be reset by removing the batteries from both t
37Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage,
38IPI Electronic Ignition Parts List – Standard System Item No. Part No. Description 1 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/
4Infinite Wall Surround-(Covers 55-3/4"W X 24")...
40LK2 Halogen Lamp Kit Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Cod
41 Photos Bottom of Unit with IPI Module Light Module &IPI Valve
42 Close up View of IPI Module Inside of IPI Module
43 IPI Valve IPI Valve
44 Millivolt Valve & Light Module Millivolt Valve
45 Venting A. Clearance above grade, veranda, porch, deck, or balcony 12in [30cm] min.[1,2] B. Clearance to window or door that may be opened. 1
46General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only
47 Figure 2 - Flex pipe spring spacing guide. Horizontal runs require support metal straps every 2ft. In an offset installation support straps
48 Horizontal Vent Table To use the Horizontal Vent Table (see Table 1), determine the total vertical height of the system and the number of bends r
49Venting Examples All horizontal runs have a minimum ¼” rise per foot.
5Pre-Installation Questions and Answers Why does my fireplace or stove give off odour? It is normal for your fireplace to give off some odour. This i
50Installation of Side Wall Venting The minimum distance from the bottom of fireplace to centre of vent is 51-1/2". For combustible walls: Cut a
51Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space w
52Flue Restrictor Adjustment MQRB5143 –All Models The Flue Restrictor is located in the top of the Firebox in front of the Flue Opening. For vertic
53 Figure 6 - Clearances in horizontal venting. Figure 7 - a) Straight-through roof support configuration; b) Flex bend configuration; c) Terminat
MQRB5143 -Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -51” Wide Listed for USA/Canada as a Decorative Appliance: Linear LH Bu
55MQG5W Decorative Ember Glass - White - 5 lbs MQG5B Decorative Ember Glass - Black - 5 lbs MQG5T Decorative Ember Glass - Turquoise - 5 lbs MQG5C
561000-215 Pal Nut (18MMXI.5MM) BLK (1364.03) 1000-218 Switch Ivory (1451/001) 1000-227 Cover Ivory (86001/001) 1000-255 Orifice Brass -(State S
57Warranty
6 Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installatio
7Installation and Operation Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building
813. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace a
9 MQRB5143 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated
Comments to this Manuals