Marquis IDV36 Operations Instructions

Browse online or download Operations Instructions for Fireplaces Marquis IDV36. Marquis IDV36 Operating instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 72
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
WARNING: If the information in these instructions is not followed
exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
Warning: Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal injury or loss of
life. Refer to this manual. Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
-What To Do If You Smell Gas
Do not try to light any appliance.
Extinguish any open flame.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
If you can not reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
WARNING: The
IDV26/IDV33/IDV36 Fireplace Insert
was designed for installation in a
solid fuel fireplace that has been
installed in accordance with
national, provincial/state and local
building codes and is constructed
of noncombustible materials. Do not
remove any refractory materials
from any masonry solid fuel
fireplace.
The IDV26/IDV33/IDV36 Fireplace
Insert was designed for installation in a
zero clearance type listed solid fuel
burning factory built fireplace. It may
be necessary to remove the damper
plate, refractory liners, log grates,
glass door, and screen rails/mesh.
Removal of the smoke baffle is
necessary in most cases.
Installation Instructions
Gas Fired Direct Vent Room Heater Inserts
Listed Certified for USA. and Canada
Model Numbers:
IDV26
Stock Numbers: IDV26N, IDV26LP, IDV26NE,IDV26LPE
Minimum Fireplace Opening Required: 33”W x 19-1/2”H x 14-1/4”D Components In
28”W x 19-1/2”H x 14-1/4”D Components Out
IDV33 - Stock Numbers: IDV33N, IDV33NE, IDV33LP, IDV33LPE
Minimum Fireplace Opening Required: 26-1/4”W x 21-3/8”H x 14-3/8”D
IDV36 Stock Numbers: IDV36N, IDV36NE, IDV36LP, IDV36LPE
Minimum Fireplace Opening Required: 30-3/4”W x 25-5/8”H x 14-3/8”D
Are Certified to: ANSI Z21.88-2009, CSA 2.33-2009, CGA 2.17-M91
FOR YOUR SAFETY
Read this complete manual before beginning installation.
These instructions must be kept with the unit for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other
g
ases, unless a certified kit is used.
A Division of R-Co. Inc.
2340 Logan Avenue
Winnipeg, Manitoba, Canada R2R 2V3
Ph:
(
204
)
632-1962
Printed in Canada October 9, 2012 Part # 26IDV-MAN
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Page view 0
1 2 3 4 5 6 ... 71 72

Summary of Contents

Page 1 - FOR YOUR SAFETY

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or

Page 2 - Operating Instructions

I26CV Clean View and Surround Sizes *The Clean Views and Surrounds in this section must be used with Valve Control Components inside the opening (as s

Page 3 - Table of Contents

I26CV1DS IDV26 *The Clean View Designer Door and optional surround in this section must be used with Valve Control Components inside the ope

Page 4

IDV26 I26SU Universal Surround A Universal Surround is available for the IDV26. This is provided as a flat sheet which mounts onto the unit and i

Page 5

I26SU UNIVERSAL SURROUND I26CVPFI26CVPF2BOTTOM OF UNIT 13

Page 6

I26CV - Surround Installation -Clean View (CV) Attachment -Valve Access 1. Optional Surround Kit (I26S, I26SPF, I26SU) is fastened to the

Page 7 - Massachusetts

I26S1 / I26SPF1 / I26SU Surround Installation Component List: I26S1 / I26SPF1 / I26SU Surround, [Qty 4] #6 Black Combo Screws Bend Up All 4 Mount

Page 8 - Important Information

I26CV2 / I26CVPF2 Wide Clean View Installation Component List:  I26CV2 or I26CVPF2 Clean View  On/ Off Switch Extension Bracket  Fan Control

Page 9 - 30-7/8”*

I26CV2 / I26CVPF2 Wide Clean View Installation -Components Out- Fan Control Switch Bracket On/Off Switch Bracket Remove On/Off Switch and original

Page 10

IDV33 Insert Dimensions and Sizing I33CV Clean View and Surround Sizes Min. Coverage with Optional I33LK or I33CV Base Unit I33LK I33CV F

Page 11 - I26CV1DS IDV26

I33LK Louver Kit and Surround Sizes NOTE: The Surrounds shown here are universal and can be used with the I33CV model. Furthermore, the I33S4535B a

Page 12

Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove pa

Page 13 - I26SU UNIVERSAL SURROUND

IDV36 Insert Dimensions and Sizing I36CV Clean View and Surround Sizes Min. Coverage with Optional I36LK or I36CV Base Unit I36LK I36CV Fro

Page 14 - -Valve Access

I36LK Louver Kit and Surround Sizes NOTE: The Surrounds shown here are universal and can be used with the I36CV model. Furthermore, the I33S4535B

Page 15 - Bend Up All 4 Mount Tabs

I33CV/I36CV Front Face and Surround Attachment Installation 1. Remove the Top Filler Panel to install vent adapter and venting to the unit. Once th

Page 16

I33LK/I36LK Front Face Attachment Installation 1. Remove the Top Filler piece from the Base unit by unfastening its three [3] screws. This part is

Page 17

Surround Installation for IDV33/IDV36 Fronts 1. Ensure that the I33LK/I36LK Front is installed before continuing with these steps. 2. When instal

Page 18 - Height:

IDV26 / IDV33 / IDV36 Wall Coverings All wall coverings below Combustible Mantel Line MUST be Non-Combustible (e.g. steel studs and con

Page 19

IDV26/IDV33/IDV36 Clearance to Combustible Mantels Before installing any mantels it is important to determine the combustibility of its material(s).

Page 20 - Base Unit I36LK I36CV

IDV26 / IDV33 / IDV36 Venting This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. This appl

Page 21

IDV26 / IDV33 / IDV36 Installation of Vent Pipe 1. Remove the Top Filler and adapter plate from the unit by removing the five [5] screws as shown

Page 22

Insulation of Chimney Cavity IDV26 / IDV33 / IDV36 If You Live In A Cold Climate Zone And Your Chimney Is On The Side Of Your House In cold cl

Page 23

Table of Contents Pre-installation Questions and Answers...

Page 24

IDV26 / IDV33 / IDV36 Riser Kit and Leveling Instructions Leveling Instructions When installing insert it may be necessary to support back of unit. T

Page 25

IDV26 / IDV33 / IDV36 Glass Door Information Glass Cleaning It will be necessary to clean the glass periodically. During start-up condensation will

Page 26 - (IDV26 This Side Only)

IDV26PRL - Porcelain Liner Panels- To Remove: 1. Remove Log Supports. Remove the [5] screws in the firebox top holding the Baffle in plac

Page 27 - #0923GK

IDV26RL - Brick Liner Panels- To Install: 1. Remove the Baffle. Remove the [5] screws in the firebox top holding the Baffle in place. Rem

Page 28

IDV33 / IDV36 Brick Liner and Liner Panel Installation Instructions For IDV33 & IDV36 Brick Liners 1. Remove the glass door. If a flat black re

Page 29 - Intermittent Mode

IDV33/36PRL- Removing and Installing Generation 2 Liner Panels- To Remove: 1. Lift Log Supports out of fireplace. 2. Remove the 2 Screws in the

Page 30

IDV33/IDV36 Overlay and Double Door Installation IDV33 Overlay This style of Overlay mounts in the square notch cutout as shown in the illustration

Page 31 - Warning and Cautions

Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/C

Page 32

IDV33 / IDV36 Burner Installation/Removal Burner System 1. Remove glass door assembly and logs (if installed). Be careful with logs as they becom

Page 33

IDV26 Burner Installation/Removal Burner Pan Removal Step 1: Disconnect pilot lines and gas supply line from valve on the side of the unit. NOTE: C

Page 34

Millivolt System, Lighting, and Burner Control... 4

Page 35

IDV26 -Millivolt- -Control Components Outside the Opening- -COMPONENTS OUT- This procedure must be done Before the unit is insi

Page 36

Fasten Component Panel at top. Replace Side Plate. Attach Component Panel and Extended Switch Bracket. Procedure is complete. IDV26 -IPI- -C

Page 37 - Gas Line Installation

Replace Side Plate. Fasten Component Panel at top & bottom. Attach Component Panel and Extended Switch Bracket (see millivolt section). Procedu

Page 38

IDV26 Fan Speed Control Outside COMPONENTS OUT NOTE: It is not necessary to disconnect fan wiring to complete this procedure. This procedure

Page 39 - CAUTION

IDV26 Optional Fan Removal / Installation The fan can be accessed from the back of the unit (which is easiest on an uninstalled unit) or throu

Page 40

IDV26 Fan - Wiring IDV26 45

Page 41

IDV33 / IDV36 Fan Installation/Removal IDV33 / IDV36 Fan System WARNING Electrical Grounding Instructions This appliance is equipped with a thr

Page 42 - Panel with Zip Tie

IDV33/IDV36 Insert Burner Component List ITEM NO. PART DESCRIPTION Qty. 1 3620-105 Burner Bracket 1 2 3620-105L Burner Bracket 1 3 DVI33-107 B

Page 43 - Left Side of Fireplace

Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING BEFORE LIGHTING A This appliance has a pilot which must be ligh

Page 44 - WARNING

IDV26 Remote Receiver Location All Units Connecting to the Gas Valve The wiring harness for the Proflame GTM system has two wires labeled “TH” &

Page 45

Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installatio

Page 46

IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standing

Page 47

IPI Electronic Ignition System the receiver and then press the power button [5] on the transmitter. An audible beep will sound to indicate the system

Page 48

IPI Electronic Ignition System Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities. Configuration #2: Remote ON/OFF and manual HI

Page 49

Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, p

Page 50

IDV26 LOGF26 DC BAA B C D 1 1 2 23 3 4 455 7 6 76891010 889 WARNING: Failure to position the parts in accordance with these diagrams o

Page 51

IDV26 LOGF27 1 2 3 4 56 ABC D1 23 45 6 4ABC D WARNING: Failure to position the parts in accordance with these diagrams or failu

Page 52 - 1001-P221SI

Log Placement – LOGF35 LOGF35 Log Set and Glowing Embers Parts List This illustration shows the rear log positioning bracket and 4 pin locating posi

Page 53 - TO TURN OFF GAS

Log Placement – LOGF36 LOGF36 Log Set includes Glowing Embers, Lava Rock, and Vermiculite. Place Log #1 onto rear log holder and center. Place Log

Page 54 - IDV26 LOGF26

MQRSP4 / MQRSP8 Rock and Glass Support Platform Installation IDV26 / IDV33 / IDV36 Preparation: Remove Grate Bar and replace screws. Remove Em

Page 55 - IDV26 LOGF27

RSP10 Glass Support Platform -Installation IDV26 / IDV33 / IDV36 Preparation: Remove Grate Bar and replace screws. Remove Ember Plates. Do not remo

Page 56 - Log Placement – LOGF35

Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local

Page 57 - Log Placement – LOGF36

MQROCK2 / MQROCK3 -MQRSP4 IDV26 / IDV33 / IDV36 MQRSP4 Parts List 1Ea Rock Support 1Ea Ember Plates Assembly Remove the ember plates

Page 58 - Plate is all that is

MQROCK2/ MQROCK3 -MQRSP4 for IDV26 / IDV33 / IDV36 (continued) Step 4: Place Rocks #6 into position as shown above. Step 5: Place Rocks #3 into p

Page 59

MQStone MQRSP8 IDV26 / IDV33 / IDV36 Decorative Stone Set. Supplied for MQRSP8 only. Begin by placing larger stones inside burner tu

Page 60

Glass Ember / MQ Ember Installation -MQRSP8 / RSP10- IDV26 / IDV33 / IDV36 MQ DEALER ONLY Spread glass or ember chunks onto tray and burner. Ensure

Page 61 - Finished Rock Set and Burn

Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation sh

Page 62 - Pilot Area MUST

Conversion Kit Instructions – PART A PLEASE CONFIRM THAT STEP 4 IS UNDERSTOOD BEFORE PROCEEDING WITH CONVERSION. WARNING: This conversion kit

Page 63

Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG

Page 64 - -CAUTION

Gas Conversion for Modulator – PART C -WARNING!- -WARNING!- 67

Page 65 - Caution:

Troubleshooting the Gas Control System Problem Possible Causes Corrective Action Defective or misaligned electrode at pilot. Check for spark at

Page 66

IDV26 Parts List Part No. Description Fireplace Base Unit IDV26N [Millivolt] IDV26NE [IPI] INSERT DIRECT VENT FIREPLACE Natural Gas 30,000 BTU IDV26

Page 67 - ARNING!

• Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat

Page 68

VI30GBL Grill Kit – Black Fireplace Accessories for IDV33 (Both Front Kits) Door Frame Overlays Z33ADDX Arch Door Frame – Deluxe Black (352) Z33ADTH

Page 69 - IDV33 Parts List

Parts for IDV26/ IDV33/ IDV36 Part No. Description Riser Kits I33R40 2-1/2” Riser for use with I33S4028B and I36S3931B I33R44 2-1/2” Riser for use

Page 70 - IDV36 Parts List

This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation and only if the unit is installed insi

Page 71

Important Information INSTALLATIONS  The following label (supplied with the gas fireplace insert) must be attached with rivets or screws to the

Page 72

IDV26 Insert Dimensions and Sizing Top View- Components In (As Shipped) Minimum Opening Dimensions Dimension Components In

Comments to this Manuals

No comments